03 - Verification · 2026 / 検証 / Public measurement data

We measured everything. Twice.

Sphinx 101 ships with the same test results we run on every build. Thirteen independent suites. 2,000+ automated measurements. The raw data is yours to inspect - we are improving everything continuously, and Sphinx 101 is work in progress with the community.

Sphinx Channel ships with the same test results we run on every build: full signal chain integrity, component-model verification, alias regression, and per-instance variation - measured on every release, with the exact per-suite counts listed in the shipped reports.

Read more about our currently simulated analog circuit physics here.

Every suite is also validated with real music material alongside the synthetic test signals. A calibrated commercial master is pushed through the actual welcome preset and metered the way a DAW meter does - because mono and synthetic tones can mislead on level. It is the authoritative check that the chain stays loudness-transparent on real, bass-heavy, stereo program material.

  • 2,000+
    Total measurements
  • 13
    Independent test suites
  • 0
    Failures
  • 0
    Warnings
01 / Downloads

Reports and raw archives. All transparent, always public.

Signal analysis - Hammerstein, THD, and phase response across the SLL, Nevy, and Amok circuits. Click to enlarge.
01 Test Summary - overview All thirteen suites at a glance · pass/fail status across 2,000+ measurements TXT · v1.6.9 view   download
02 Signal-chain verification 1,035 measurements · end-to-end gain, phase, polarity, bypass residue TXT · v1.6.9 view   download
03 Compressor verification 217 measurements · attack / release accuracy across all four topologies TXT · v1.6.9 view   download
04 EQ verification 170 measurements · band response and inductor saturation under load TXT · v1.6.9 view   download
05 Transformer verification 220 measurements · four iron cores (M1166 / C9049 / K1166 / L1544) - saturation, hysteresis, FR, phase, drive sweep TXT · v1.6.9 view   download
06 Module verification 130 measurements · per-module crosstalk and signal isolation TXT · v1.6.9 view   download
07 Parameter verification 175 measurements · every parameter swept across its full range TXT · v1.6.9 view   download
08 Oversampling and anti-aliasing 60 measurements · 44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz consistency TXT · v1.6.9 view   download
09 Component-model verification 68 measurements · mathematical building blocks (Koren triode / BJT / VCA / op-amp / passives / Jiles-Atherton / VU / PPM / LED) plus 30 edge-case robustness tests TXT · v1.6.9 view   download
10 Configuration audit 63 measurements · internal coherence of every config and circuit selection TXT · v1.6.9 view   download
11 Noise model verification 37 measurements · per-topology noise-floor and PSRR regression gate across every personality × compressor combination plus Width tube engagement TXT · v1.6.9 view   download
12 HF alias regression 10 measurements · 15 kHz / −6 dBFS probe through each nonlinear element in isolation plus the full chain; per-item baseline + 3 dB regression headroom TXT · v1.6.9 view   download
13 Plugin-path alias regression 5 measurements · 15 kHz / −6 dBFS probe through the full plugin processBlock at every oversampling factor (2× / 4× / 8× / 16×) plus a separate extreme-settings case; per-OS regression gate TXT · v1.6.9 view   download
14 Per-instance variation 315 measurements · 1 kHz / −6 dBFS probe across 16 seeds × 3 topologies × 2 tiers; per-instance Hammerstein rank-stability and THD spread gate so every instance lands in the same harmonic-ordering regime TXT · v1.6.9 view   download
Check them yourself. Compare against your own hardware if you have it. Give the reports to your AI of choice to explain. We publish what we measure because we expect you to verify - most analog-simulating audio plugins ship just a promising press release; we ship the raw and verified test results. Sphinx 101 is work in progress, and gets better with every update. Download the free demo.
  • 1,000+
    Total measurements
  • 12
    Independent test suites
  • 0
    Failures
  • 0
    Warnings
01 / Downloads

Reports and raw archives. All transparent, always public.

Signal analysis - Hammerstein, THD, and phase response across the SLL, Nevy, and Amok circuits. Click to enlarge.
01 Test Summary - overview All twelve suites at a glance · pass/fail status across 1,395 measurements TXT · v1.0.1 view   download
02 Signal-chain verification 693 measurements · end-to-end gain, phase, polarity, bypass residue, envelope preservation, real-music material integrity TXT · v1.0.1 view   download
03 Transformer verification 138 measurements · four iron cores (M1166 / C9049 / K1166 / L1544) - saturation, hysteresis, FR, phase, drive sweep TXT · v1.0.1 view   download
04 Module verification 45 measurements · per-module crosstalk and signal isolation across transformer, drive, and width stages TXT · v1.0.1 view   download
05 Parameter verification 35 measurements · every parameter swept across its full range TXT · v1.0.1 view   download
06 Oversampling and anti-aliasing 60 measurements · 44.1 / 48 / 88.2 / 96 / 192 kHz consistency TXT · v1.0.1 view   download
07 Component-model verification 46 measurements · mathematical building blocks (Koren triode / Ebers-Moll BJT / Jiles-Atherton cores / VU / LED) plus edge-case robustness tests TXT · v1.0.1 view   download
08 Configuration audit 17 measurements · internal coherence of every circuit, transformer, and TrueRail tier selection TXT · v1.0.1 view   download
09 Noise model verification 16 measurements · noise-floor regression gate across every personality × buffer-size combination plus Width tube engagement TXT · v1.0.1 view   download
10 Transition-click verification 22 measurements · every enable and selector transition gated for click-free behavior TXT · v1.0.1 view   download
11 HF alias regression 3 measurements · 15 kHz / −6 dBFS probe through each nonlinear element in isolation; per-item baseline + 3 dB regression headroom TXT · v1.0.1 view   download
12 Plugin-path alias regression 5 measurements · 15 kHz / −6 dBFS probe through the full plugin processBlock at every oversampling factor (2× / 4× / 8× / 16×) plus a separate extreme-settings case TXT · v1.0.1 view   download
13 Per-instance variation 315 measurements · 1 kHz / −6 dBFS probe across 16 seeds × 3 topologies × 2 tiers; Hammerstein rank-stability and THD spread gate TXT · v1.0.1 view   download
Check them yourself. Compare against your own hardware if you have it. Give the reports to your AI of choice to explain. The same reports ship inside every Sphinx Channel installer, next to the manual. Beyond the synthetic signals, the battery runs a real-music level section: a calibrated commercial master through the actual welcome preset, metered the way a DAW meter does - the authoritative check that the chain stays loudness-transparent on real, bass-heavy, stereo program material. Sphinx Channel is work in progress, and gets better with every update. Download the free demo.