SPHINX CHANNEL - Changelog Analog Realism https://analogrealism.com ======================================= v1.1.2 - 2026-09-13 - Nevy skin TX selector fix Fixed: - On Nevy skin (dark), the A2503 and C9049 transformer position were wrongly shown in mirrored locations, while Amok showed correctly - A2503 is at 8-clock and C9049 at 2-clock. Now both skins show identical and correct positions for transformer selection. v1.1.1 - 2026-09-11 - APY iron improvements Fixed: - The APY circuit's built-in console output iron now resets its magnetic state when the host stops and restarts the audio stream, like the input transformer does. Previously a stopped session could carry a small amount of magnetic history into the next playback. - The APY circuit's built-in iron now responds to the Device Age control and to the modeled chassis temperature, like every other transformer core. At the default Age setting the change is at the threshold of measurability. v1.1.0 - 2026-09-10 - APY circuit, A2503 transformer, metering, output gain, groups New: - APY main circuit added. An American discrete op-amp recording console that carries its own inline output iron. Its low-end grit falls as you drive harder, the signature of this hardware class. Fast and punchy with an iron-forward low end. Instances running APY share the same virtual power supply as every other instance, whichever circuits they run. - A2503 transformer model added. A known console core with the highest headroom of the five models, sitting between the iron trio and the transparent L1544. - Output Gain control added. A final level trim at the end of the strip. Hold Shift while dragging either gain knob to inverse-link the pair, so pushing the input automatically trims the output to hold level. - Meter-switch selector: switches the meters between reading the input or the output signal level. - GROUP remote control button added. Each plugin carries a group letter (A to H), and arming the GROUP button broadcasts changes only to strips sharing that letter. The ALL button still remote controls every strip. TrueRail voltage rail capacity is shared between all groups and main circuits for realistic summing across the board. - VST3 users: the new circuit and transformer options extended the selector ranges. Existing VST3 automation lanes written for those selectors should be checked after updating. AU sessions are unaffected. Fixed: - Reported latency at 16x oversampling was one sample short. Hosts now delay-compensate exactly at every oversampling setting, and null tests align sample-accurately at 16x. - Mono instances now mirror the level meter to both LED columns and show a MONO badge, instead of leaving the right column dark. - Test reports expanded to cover the APY circuit and the A2503 transformer alongside the existing options. v1.0.2 - 2026-09-03 - AAX Support New: - Avid AAX support added. v1.0.1 - 2026-08-29 - Oversampling low-end fix Fixed: - Selecting oversampling settings above 2x started thinning the low-end response. Now low-end stays full with any OS position. v1.0.0 - 2026-08-24 - Initial release New: - Component-modeled input chain: input transformer with four selectable cores, discrete drive circuitry in three topologies (SLL, Nevy, Amok), TrueRail power-supply grades, and stereo width. - Shared-console behavior: instances in one session share supply load, mains-ripple phase, and signal ground. A single instance is unaffected. - ALL button: broadcasts control changes, preset loads, window size, and skin to every instance in the session. - Preset system: factory bank, user presets, and a Default preset that defines the fresh-instance state. - Two visual skins (Nevy, Amok) and continuous window resizing, each instance remembering its own settings, preset, skin, and size. - Metering calibrated to studio alignment: VU at 0 VU = -18 dBFS RMS (EBU-style channel alignment), five input LEDs per side at -18 / -12 / -6 / -3 / 0 dBFS. - Calibrated defaults chosen by ear: transformer L1544 at 120 percent drive, SLL circuit, TrueRail C, width on at +6 percent. - Signal test results included: twelve automated verification suites, report files installed alongside the manual.